If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
Bridge Diodes Absolute Maximum Ratings Parameter Type No. VRM (V) IF (AV) (A) With Heatsink Electrical Characteristics (Ta = 25C) Tstg (C) VF (V) max per IF element (A) IR (A) VR = VRM IR (H) (A) VR=VRM, Tj=100C Rth ( j-c) (C/ W) Others Mass Fig. (g) IFSM (A) 50Hz Half-cycle Sinewave Single Shot Tj (C) max per element max per element RBV-1306 RBV-1506S 600 13 80 150 1.2 1.1 -40 to +150 6.5 10 100 15 200 25 350 7.5 200 1.05 50 12.5 1.5 6.45 A RBV-1506 RBV-2506 RBV-1306 Tc--IF(AV) Derating 14 Average Forward Current IF (AV) (A) Forward Power Loss Pf (W) IF(AV)--Pf Characteristics 50 IFSM (A) 80 IFMS Rating IFSM (A) Tj = 150C 12 10 t /T= 1/ 3, Sinewave t /T = 1/2 D.C. 40 8 6 4 2 0 30 t /T= 1/ 3, Sinewave t /T = 1/2 D.C. Peak Forward Surge Current t T 20ms 60 40 20 20 10 20 40 60 80 100 120 140 Case Temperature Tc (C) 160 0 2 4 6 8 10 12 14 Average Forward Current IF (AV) (A) 0 1 5 10 Overcurrent Cycles 50 RBV-1506S Tc--IF(AV) Derating 15 Average Forward Current IF (AV) (A) IF(AV)-- Pf Characteristics IFSM (A) IFMS Rating 150 IFSM (A) t /T = 1/2 Forward Power Loss Pf (W) 50 Tj = 150C t T t /T= 1/ 3, Sinewave t /T= 1/ 3, Sinewave 12 t /T = 1/6 9 D.C. 40 20ms t /T = 1/6 30 Peak Forward Surge Current 100 6 20 t /T = 1/2 10 D.C. 50 3 0 0 20 40 60 80 100 120 140 160 Case Temperature Tc (C) 0 0 2 4 6 8 10 12 14 16 Average Forward Current IF (AV) (A) 0 1 5 10 Overcurrent Cycles 50 RBV-1506 Tc--IF(AV) Derating 15 Average Forward Current IF (AV) (A) IF(AV)--Pf Characteristics IFSM (A) IFMS Rating 200 IFSM (A) t /T = 1/2 Forward Power Loss Pf (W) 50 Tj = 150C t T t /T= 1/ 3, Sinewave t /T = 1/6 12 t /T =1/ 3, Sinewave t /T = 1/6 D.C. 40 20ms 150 9 30 Peak Forward Surge Current 100 6 20 t /T = 1/2 3 10 D.C. 50 0 0 20 40 60 80 100 120 140 160 Case Temperature Tc (C) 0 0 2 4 6 8 10 12 14 16 Average Forward Current IF (AV) (A) 0 1 5 10 Overcurrent Cycles 50 External Dimensions (Unit: mm) Flammability: UL94V-0 or Equivalent Fig. A C3 30 3.2 0.1 4.6 3.6 + 4-1.0 10 - 11 13 0.7 17.5 20.0 7.5 7.5 2.7 + - 22 RBV-2506 Tc --IF(AV) Derating 25 Average Forward Current IF (AV) (A) IF(AV)--Pf Characteristics 100 IFSM (A) 350 300 250 200 150 100 50 IFMS Rating IFSM (A) t /T = 1/2 Forward Power Loss Pf (W) Tj =150C 80 20 t /T= 1/ 3, Sinewave 15 t /T = 1/6 D.C. t T t /T = 1/6 t /T= 1/ 3, Sinewave 20ms 60 10 40 t /T = 1/2 20 D.C. 5 0 0 20 40 60 80 100 120 140 160 Case Temperature Tc (C) 0 Peak Forward Surge Current 0 4 8 12 16 20 24 28 32 Average Forward Current IF(AV) (A) 0 1 5 10 Overcurrent Cycles 50 23 |
Price & Availability of RBV-2506 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |